IIS Settings for TCP Web Optimisation
These are settings to be changed on IIS after it has been installed
On the Website
These settings are under the advanced settings on the Website
Set Preload to be True
On the Application Pool
These settings are under the advanced settings on the Application Pool
Set Enabled 32bit to False
Set Start Mode to always Running
Set Idle Timeout to 0
Recycling
The default setting for the App worker recycling is 29 hours. This can lead to unnecessary high memory usage when Portal Ordering/Kiosk is configured.
Change this to 360 minutes
Related Articles
TCP 'Cloud' Web Server Specification
Overview TCP v2.10 is the first version that includes native web provided functionality. The intention is that a separate Web Server is provided to run alongside the TCP application server. The document gives an initial specification we expect that ...
TCP Web Adverts
TCP Web Adverts User Guide TCP WEB ADVERTS USER GUIDE Notes Please note that TCP Web Users can be locked down so you may have to request access to parts of the system. Login The First step to setting up Adverts is to Log in to TCP Web. Once logged in ...
Aures EFT COM Settings
Open Device Manager in Control Panel, then double-click on the Communications Port (COMXX) that the EFT is connected to. On the Port Settings tab, change the Bits per second value to match the value shown when setting up the Pinpad connection in ...
GPoS / TCP - Hostname for Comms (Applies to Gpos 1.64 / TCP 2.11 onwards)
With the arrival of TCP 2.11 and Gpos 1.64 communications to Total Control Premier have changed. instead of the traditional method of an IP address, it now uses the hostname of the hardware. The naming is absolute and must match exactly including any ...
Total Control Premier Cloud Edition Setup
This article applies to Total Control Premier version 2.11 and higher - screenshots are taken from Total Control Premier version 2.11. Before You Begin Total Control Premier Cloud Edition is a web application running on Internet Information Services, ...